Conformity to the Low Voltage Directive in the EU (Continued)
■HP rating
Inverter type
1
FRN001AR1 -2U
2
FRN002AR1 -2U
3
FRN003AR1 -2U
5
FRN005AR1 -2U
7
FRN007AR1 -2U
10
FRN010AR1 -2U
15
FRN015AR1 -2U
20
FRN020AR1 -2U
25
FRN025AR1 -2U
30
FRN030AR1 -2U
40
FRN040AR1 -2U
50
FRN050AR1 -2U
60
FRN060AR1 -2U
75
FRN075AR1S-2U
100
FRN100AR1S-2U
125
FRN125AR1S-2U
Note: A box ( ) replaces an alphabetic letter depending on the enclosure.
Enclosure: M (IP21) or L (IP55)
3. When used with the inverter, a molded case circuit breaker (MCCB), residual-current-operated protective
device (RCD)/earth leakage circuit breaker (ELCB) or magnetic contactor (MC) should conform to the EN
or IEC standards.
4. When you use a residual-current-operated protective device (RCD)/earth leakage circuit breaker (ELCB)
for protection from electric shock in direct or indirect contact power lines or nodes, be sure to install type
B of RCD/ELCB on the input (primary) of the inverter.
5. The inverter should be used in an environment that does not exceed Pollution Degree 2 requirements.
6. Install the inverter, AC reactor (ACR), input or output filter in an enclosure with minimum degree of
protection of IP2X (Top surface of enclosure shall be minimum IP4X when it can be easily accessed), to
prevent human body from touching directly to live parts of these equipment.
Note: Does not apply to IP55 model.
7. Do not connect any copper wire directly to grounding terminals. Use crimp terminals with tin or equivalent
plating to connect them.
8. When you use an inverter at an altitude of more than 2000 m, you should apply basic insulation for the
control circuits of the inverter. The inverter cannot be used at altitudes of more than 3000 m.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Fuse rating
(A)
6(IEC/EN 60269-2)
10(IEC/EN 60269-2)
16(IEC/EN 60269-2)
25(IEC/EN 60269-2)
35(IEC/EN 60269-2)
50(IEC/EN 60269-2)
80(IEC/EN 60269-2)
100(IEC/EN 60269-2)
125(IEC/EN 60269-2)
250(IEC 60269-4)
350(IEC 60269-4)
450(IEC 60269-4)
500(IEC 60269-4)
vii
Inverter type
1
FRN001AR1 -4U
4(IEC/EN 60269-2)
2
FRN002AR1 -4U
6(IEC/EN 60269-2)
3
FRN003AR1 -4U
10(IEC/EN 60269-2)
5
FRN005AR1 -4U
16(IEC/EN 60269-2)
7
FRN007AR1 -4U
20(IEC/EN 60269-2)
10
FRN010AR1 -4U
25(IEC/EN 60269-2)
15
FRN015AR1 -4U
35(IEC/EN 60269-2)
20
FRN020AR1 -4U
50(IEC/EN 60269-2)
25
FRN025AR1 -4U
63(IEC/EN 60269-2)
30
FRN030AR1 -4U
80(IEC/EN 60269-2)
40
FRN040AR1 -4U
100(IEC/EN 60269-2)
50
FRN050AR1 -4U
125(IEC/EN 60269-2)
60
FRN060AR1 -4U
250(IEC 60269-4)
75
FRN075AR1 -4U
100
FRN100AR1 -4U
125
FRN125AR1 -4U
350(IEC 60269-4)
150
FRN150AR1S-4U
200
FRN200AR1S-4U
400 (IEC 60269-4)
250
FRN250AR1S-4U
450 (IEC 60269-4)
300
FRN300AR1S-4U
500 (IEC 60269-4)
350
FRN350AR1S-4U
550 (IEC 60269-4)
450
FRN450AR1S-4U
630 (IEC 60269-4)
500
FRN500AR1S-4U
900 (IEC 60269-4)
600
FRN600AR1S-4U
1250 (IEC 60269-4)
800
FRN800AR1S-4U
900
FRN900AR1S-4U
2000 (IEC 60269-4)
1000
FRN1000AR1S-4U
Fuse rating
(A)