Operational Check - Assa Abloy Sargent SE LP10 Installation Instructions Manual

Mortise lock

Advertisement

Operational Check

8
For 82280-82283 & 82270-82273 Function mortise locks with cylinders:
A. Insert key into cylinder and rotate: There should be no friction against lock case, wire harness
or any other obstructions.
B. The key will retract the latch: Key should rotate freely.
C. When the deadbolt is thrown: Ensure that the key retracts both the deadbolt and the latch.
D. Inside lever: When used, ensure it retracts both the latch and deadbolt (if provided).
E. Close door: Ensure latch and deadbolt fully extend and do not bind.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field*. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
*For directions on use, see operating
instructions provided with unit.
Feature
12 or 24VDC solenoid lock
voltage adjustable
Operates as Fail Safe or
Fail Secure
"Learn" mode allows testing
of specific cards without
programming at panel level
Card reader data integrity is
validated at test unit
Displays detailed Wiegand
data, including hexadecimal
string and total bits received
Displays measured end-of-line
resistor values (if applicable)
20
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
SE LP10 Mortise Lock
WT1
WT2
X
X
X
X
X
X
X
X
X
X