SE LP10 Mortise Lock
Typical (UL294-Compliant) SE LP10 Mortise Application Diagram #1
Tamper will trigger when reader is removed from door and tamper wiring is connected at the panel.
12 Conductor
ElectroLynx Harness
From McKinney
SE LP10
*IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
*UL294 is a United States based standard.
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
12/24VDC System
12V
Average
Peak
Reader
100mA
220mA
Actuator
15mA
500mA
QC12 Electric
Hinge From
READER NEG - Black, 1
McKinney
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
TAMPER - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
24V
Average
Peak
n/a
n/a
15mA
500mA
H
N
G
120 VAC
12-24VDC
12VDC
Input
-
+
-
+
(-)
12VDC
(+)
DATA 1
DATA 0
RX (NO)
RX (COM)
DPS
DPS
5VDC
Input
Connection (+)
Unsupervised Open
Input
Connection (-)
Collector Tamper
9
Power Supply
(By Others)
Electrical
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock Relay
(NO) Fail
Secure
Operation
Panel Circuitry
1KΩ
1KΩ
A to D Converter
1KΩ