CL33600 Series Cylindrical Lock
Mechanical
Before closing door test for cylinder function of lock cylinder
and Inside lever:
a. Insert key into cylinder and rotate.
b. The key will retract the latch. Key should rotate freely.
c. Inside lever retracts latch.
d. Close door, ensure latch fully extends into strike
and does not bind.
Electrical
Note: Once electrical wiring has been successfully
completed according to proper application, perform
the following step:
a. Turn power ON.
b. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
c. Present proximity credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., when prox
credential is presented to reader that the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

8) Operational Check

15
Feature
WT1
12 or 24VDC solenoid
X
lock voltage adjustable
Operates as Fail Safe or
X
Fail Secure
"Learn" mode allows
testing of specific cards
X
without programming at
the panel level
Card reader data inte-
grity is validated at test
X
unit
Works with SE LP10
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
WT2
X
X
X
X
X
X
X

Advertisement