Operational Check - Assa Abloy Corbin Russwin SE LP10 MP9800 Series Installation Instructions Manual

Integrated wiegand with and without melr option
Table of Contents

Advertisement

SE LP10 Integrated Wiegand
With and Without MELR Option (Electric Latch Retraction)
For devices without cylinders, go to step 3.
1. For devices with cylinders, insert key into cylinder and rotate.
2. The key will retract the latch and rods, the key should rotate freely.
3. Depress inside rail to retract latch and rods.
Note: Once electrical wiring has been successfully completed
according to proper application, complete the following step:
1. Turn power ON.
2. Verify LED located on reader is ON.
Red or Green depending on reader
configuration (See reader
LED Configuration).
3. Present proximity credential and verify
LED and sounder activity.
4. Verify valid card read at EAC Panel.
5. Verify system operation functions;
i.e., when prox credential is presented
to reader that the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

9) Operational Check

17
Feature
WT1
12 or 24VDC lock
X
voltage adjustable
Operates as Fail Safe or
X
Fail Secure
"Learn" mode allows
testing of specific cards
X
without programming at
the panel level
Card reader data
integrity is validated
X
at test unit
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
WT2
X
X
X
X
X
X