Mortise lock

Advertisement

SE LP10 Mortise Lock
9 (Optional) Fire Plate Installation
A. Install the fire plate to the mounting plate (Fig 9), being careful not to
trap or pinch wires between fire plate and mounting plate. Fasten plate
with two (2) #8 x 1 1/4" Phillips pan head self-drilling screws.
B. Ensure wires from reader are properly routed under flap of fire plate.
Complete securing mounting plate by fully tightening all four
(4) mounting plate screws.
10 Outside Cylinder Installation
NOTE: Verify that the lock body wires do not contact any moving parts as cylinder and deadbolt move.
A. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 10A).
B. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig. 10B).
C. Rotate cylinder until it is nearly flush with the edge of rosette and the SARGENT
logo is positioned correctly (Fig. 10A).
Note: Do not attempt to tighten all the way.
D. Tighten the cylinder clamp set screw to prevent
unscrewing of the cylinder (Fig. 10C).
E. Test cylinder function:
• 70/71/72/73 Function:
Key retracts latch.
• 80/81/82/83 Function:
Key retracts latch and projects
and retracts deadbolt.
• Ensure smooth operation of
latchbolt and deadbolt.
NOTE: Use lever handle holes
to manipulate mortise to ease
thread engagement of cylinder.
IMPORTANT: Position cylinder so that the
SARGENT logo is positioned correctly.
Correct
Fig. 10A
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
Incorrect
Fig. 9
Outside of Door
Fig. 10B
17
*(2) Phillips
#8 x 1/2"
flat head
machine
screws
(2) Phillips
Fire
#8 x 1 1/4"
Plate
pan head
screws
Cylinder
Set Screw
Phillips
Screwdriver
Fig. 10C