Alternate Indicator Application Diagram #2 (12/24VDC System)
Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with
panel switch will override reader LED to keep it green.
Reader
Actuator
Reader Electronics Requires 12VDC Filtered and Regulated
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet A8191 for the wiring of
RX & DPS outputs.
12/24VDC System
12 Conductor
ElectroLynx Harness
From McKinney
*IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
**UL294, S319, & BHMA A156.25 currently not applicable to Alternate Indicator Configuration option
12V
Average
Peak
Average
100mA
220mA
n/a
15mA
500mA
15mA
QC12 Electric
Hinge From
READER NEG - Black, 1
McKinney
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
**GREEN_LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
10
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
SE LP10 Mortise Lock
24V
Peak
n/a
500mA
H
N
G
120 VAC
12-24VDC
12VDC
Input
-
+
-
+
(-)
12VDC
(+)
DATA 1
DATA 0
RX (NO)
RX (COM)
DPS
DPS
(NC)
(NO)
Power Supply
(By Others)
Electrical
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock Relay
(NO) Fail
Secure
Operation
Panel Circuitry
Panel Relay