18. Insert the positive and negative wires into the V+ and V- contacts on the
terminal block connector.
19. Tighten the wire-clamps screws to prevent the DC wires coming loose.
20. Take into consideration the following guidelines before wiring the
device.
21. The terminal block is suitable for 30-12 AWG (16A). Torque value 5 lb-in.
22. The temperature rating of the input connection cable should be higher
than 95°C.
23. WARNING! This equipment is intended for installation in a Restricted
Access Location only.
AVERTISSEMENT! Cet équipement est destiné à être installé dans un
lieu d'accès restreint uniquement.
24. There must be a disconnect device in front of "NISE 3800 series" to keep
the worker or field side maintainer be cautious and aware to close
the general power supply before they start to do maintenance. The
disconnect device hereby means a 20A circuit-breaker.
25. Power installation must be performed with qualified electrician and
followed with National Electrical Code, ANSI/NFPA 70 and Canadian
Electrical Code, Part I, CSA C22.1.
26. Tolerance within maximum operating voltage range 9 VDC to 36 VDC,
13.3A-4A.
Copyright © 2017 NEXCOM International Co., Ltd. All Rights Reserved.
27. WARNING! RISK OF EXPLOSION IF BATTERY IS REPLACED BY
INCORRECT BATTERY TYPE. DISPOSE OF USED BATTERIES ACCORDING
TO THE INSTRUCTIONS.
ATTENTION! IL Y A RISQUE D'EXPLOSION SI LA BATTERIE EST
REMPLACÉE PAR UNE BATTERIE DE TYPE INCORRECT. METTRE AU
REBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS.