Generator Inspection - Suzuki VLR1800 Service Manual

Table of Contents

Advertisement

1J-4 Charging System:

Generator Inspection

Generator Coil Resistance
1) Remove the left frame lower cover and secondary
gear case cover. Refer to "Exterior Parts Removal
and Installation in Section 9D (Page 9D-3)".
2) Disconnect the generator coupler (1).
1
3) Measure the resistance between the three lead
wires.
If the resistance is out of specified value, replace the
stator with a new one. Also, check that the generator
core is insulated properly.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (Ω)
Generator coil resistance
0.2 – 1.5 Ω (B – B)
∞ Ω (B – Ground)
4) Connect the generator coupler.
B822H11A06003
I822H11A0001-01
B
B
B
I718H11A0005-02
No-load Performance
1) Remove the left frame lower cover and secondary
gear case cover. Refer to "Exterior Parts Removal
and Installation in Section 9D (Page 9D-3)".
2) Disconnect the generator coupler (1).
1
3) Start the engine and keep it running at 5 000 r/min.
4) Using the multi-circuit tester, measure the voltage
between three lead wires.
If the tester reads under the specified value, replace
the generator with a new one.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Voltage (~)
Generator no-load performance (When engine is
cold)
70 V (AC) and more at 5 000 r/min
I822H11A0002-01
B
B
B
I718H11A0006-02