ICP DAS USA tDS-718i-D User Manual page 78

Table of Contents

Advertisement

Tiny Serial-to-Ethernet Device Server
The following are examples of pair-connection tests:
Pair-connection Settings:
Model
Baud
Rate
tDS-700 #1
115200
tDS-700 #2
115200
Note
The Baud Rate and Data Format settings of the client and server (tDS-700 #1 and #2) depend on the COM
ports of the PC (or the connected device). The serial port settings between tDS-700 #1 and tDS-700#2 can be
different.
Ensure that the following items are available:
 A DN-09-2F Terminal Board
(Optional, Website: http://www.icpdas.com/en/product/DN-09-2F)
 A I-7520 module
(Optional, Website: http://www.icpdas.com/en/product/I-7520)
Step 1: Connecting to a network, PC and Power
1. Confirm that the tDS-700/DS-2200 modules are functioning correctly. Refer to
"Getting Started for tDS-700
details.
2. Use a DN-09-2F wiring terminal board to connect COM1 of the PC to COM1 of the tDS-700 #1,
refer to
Section 2.6 "Wiring Notes for RS-232/485/422 Interfaces"
information.
3. Use an I-7520 module to connect COM2 of PC to COM1 of the tDS-700 #2, refer to
"Wiring Notes for RS-232/485/422 Interfaces"
※Refer to Figure 6-1 for an illustration of how to perform the above steps.
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
Port Settings
(default)
Data
Application
Format
8N1
Client
8N1
Server
series",
Chapter 4 "Getting Started for DS-2200
Pair-connection Settings
Remote
Server IP
Mode
IP Address of tDS-700 #2
for RS-422/485 wiring details information.
Remote TCP
Port
(default)
10001
-
-
Chapter 3
series"for more
for RS-232 wiring details
Section 2.6
-78 -