Tiny Serial-to-Ethernet Device Server
1. Confirm that the tDS-700/DS-2200 modules are functioning correctly. Refer to
"Getting Started for tDS-700
details.
2. Wire the slave device (e.g., M-7015, optional) with your tDS-700/DS-2200. For detailed
RS-232/422/485 wiring information, refer to
Interfaces".
3. Supply power to the slave device (e.g., M-7015, Device ID: 2, +10 to +30 V
4. Install VxComm Utility, and then configuration Ethernet setting (such as IP/Mask/Gateway
details) for tDS-700/DS-2200 series module; refer to
series",
Chapter 4 "Getting Started for DS-2200
5. Confirm the serial port settings (Baud Rate and Data Format) must be the same between the
tDS-700/DS-2200 and slave device (e.g., M-7015).
For example:
Model
tDS-700/DS-2200
Slave Device (M-7015)
6. Right click in the Port-List panel and then choose the "Open TCP Port" item under the VxComm
utility.
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
series",
Chapter 4 "Getting Started for DS-2200 series"
Section 2.6 "Wiring Notes for RS-232/485/422
series".
Port Settings
Baud Rate
9600
9600
power used.)
DC
Chapter 3 "Getting Started for tDS-700
Data Format
8,N,1