A1. How do I restore the web password for the module to the factory
default password?
The instructions below outline the procedure for resetting the web password to the factory default
Note: Be aware that ALL settings will be restored to the factory default values after the module is reset.
value.
Step 1 Locate the Init/Run switch that can be found on
the right-hand side of the tDS-700/DS-2200 module and
set it to the "Init" position. Reboot the module to load
factory default settings including default web password.
Step 2 Execute either the VxComm Utility or the eSearch Utility to search for any tDS-700/DS-2200
modules connected to the network. Verify that the tDS-700/DS-2200 has been reset to the original
factory default settings. For example, the module should be shown as having the default IP address,
which is 192.168.255.1.