Tiny Serial-to-Ethernet Device Server
Item
Serial Data Packing
Slave Timeout (ms)
Packing Length (bytes)
Serial Ending Chars
(Number[,char1][,char2])
Timeout Between Chars (ms)
Pair-Connection Settings (Client/Server Mode)
Application Mode
Remote Server IP
Remote TCP Port
Submit
Note
For more detailed information regarding pair-connection applications settings, refer to
Connection
Applications".
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
Description
Set the waiting time after last Tx of the request sent to the
device. If the device does not respond within the timeout
value, the tDS-700/DS-2200 will return existing data via TCP
package and process next request.
When the input serial data length reaches to the value, it
will be sent out.
Settings range: 0 ~ 1024;
Disabled: 0.
The tDS-700/DS-2200 outputs an Ethernet packet
immediately after the ending-chars pattern is identified
from the incoming serial data. The number of ending-chars
can be 0 (disabled), 1 or 2 chars.
Disabled=0;
1 char: 1,0x0D;
2 chars: 2,0x0D,0x0A
Set the waiting time after Rx of the response sent from the
device. If the device does not respond within the timeout
value, the tDS-700/DS-2200 will process this response.
Settings range: 10 ~ 65535;
Disabled: 0.
Server
-
-
Click this button to save the revised settings to the tDS-700/DS-2200.
Default
1000
Client
IP address of the remote device
TCP Port number of the remote
device
Section 6.4 "Pair-
0
0
10
-65 -