7.2 Limitations of the Adept DeviceNet Scanner
The DeviceNet Scanner that Adept has incorporated into the Adept SmartController EX motion
controller hardware and the eV+ operating system currently supports only a subset of full
DeviceNet functionality. The following is a summary of the DeviceNet implementation:
Implemented the Master-Slave operation. This is a complete subset of Peer-to-Peer oper-
l
ation.
Implemented the Unconnected Message Manager (UCMM) in its DeviceNet Scanner to
l
establish connections.
UCMM is used to establish I/O Connections.
l
The Adept DeviceNet Scanner can be a Client or a Server on the network.
l
The Adept DeviceNet Scanner currently does not support Cyclic or Change-of-State con-
l
nections.
Only I/O Messaging is supported. I/O messages contain only data.
l
Currently, only the Message Group 2 of the Predefined Master/Slave Connection Set is sup-
l
ported.
Adept Message Group 2 I/O connections support only the I/O Poll Command/Response
l
Message of the possible message types.
7.3 DeviceNet Port on the Controller
The DeviceNet port on the Adept SmartController EX Motion Controller has the following con-
figuration:
Micro-style 12 mm thread DIN connector (female). See the following table for pin assignments.
See the figure DeviceNet Connector Pinouts on page 93 for a drawing of the connectors.
Connecting DeviceNet Hardware to the Controller
To connect DeviceNet components to the controller, connect a drop line to the female Micro-
style 12 mm thread DIN connector on the front of the controller. Then you must configure the
DeviceNet Scanner correctly using the Adept ACE Configuration Tools.
Chapter 7: Adept DeviceNet
Table 7-1. DeviceNet Signal-to-Pin Locations
Pin
Number
1
2
3
4
5
Adept SmartController EX User's Guide, Rev.C
Page 86 of 96
Signal
Name
Drain
V+
V-
CAN_H
CAN_L