Siemens SINAMICS G120D Operating Instructions Manual page 151

Distributed inverter cu240d-2 control unit with encoder evaluation
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

PNU (parameter number) and page index
Parameter number
0000 ... 1999
2000 ... 3999
6000 ... 7999
8000 ... 9999
10000 ... 11999
20000 ... 21999
29000 ... 29999
30000 ... 31999
60000 ... 61999
Subindex
For indexed parameters, the parameter index is located in subindex as hexadecimal value.
PWE: Parameter value or connector
Parameter values or connectors can be located in the PWE.
Table 8-14
Parameter value
Connector
Examples
Read request: Read out serial number of the Power Module (p7841[2])
To obtain the value of the indexed parameter p7841, you must fill the telegram of the parameter
channel with the following data:
• PKE, Bit 12 ... 15 (AK): = 6 (request parameter value (field))
• PKE, Bit 0 ... 10 (PNU): = 1841 (parameter number without offset)
Parameter number = PNU + offset (page index)
(7841 = 1841 + 6000)
• IND, bit 8 ... 15 (subindex): = 2 (index of parameter)
Converter with the control units CU240D-2
Operating Instructions, 10/2020, FW V4.7 SP13, A5E34262100B AH
PNU
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
Parameter value or connector
PWE 1
Bit 15 ... 0
Bit 15 ... 0
Number of the connector
8.5 Drive control via PROFIBUS or PROFINET
0
0
32-bit value
Bit 15 ... 10
Advanced commissioning
Page index
0 hex
80 hex
90 hex
20 hex
A0 hex
50 hex
70 hex
F0 hex
74 hex
PWE 2
Bit 15 ... 8
Bit 7 ... 0
0
8-bit value
16-bit value
Bit 9 ... 0
3F hex
The index or bit field
number of the connec‐
tor
149