Siemens SINAMICS G120D Operating Instructions Manual page 143

Distributed inverter cu240d-2 control unit with encoder evaluation
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

Status word 3 (ZSW3)
Bit Meaning
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Converter with the control units CU240D-2
Operating Instructions, 10/2020, FW V4.7 SP13, A5E34262100B AH
1 = DC braking active
1 = |n_act | > p1226
1 = |n_act | > p1080
1 = i_act ≧ p2170
1 = |n_act | > p2155
1 = |n_act | ≦ p2155
1 = |n_act | ≧ r1119
1 = DC link voltage ≦ p2172
1 = DC link voltage > p2172
1 = ramp-up or ramp-down completed Ramp-function generator is not ac‐
1 = technology controller output at
the lower limit
1 = technology controller output at
the upper limit
Not used
Not used
Not used
Not used
8.5 Drive control via PROFIBUS or PROFINET
Description
--
Absolute current speed > stationary
state detection
Absolute actual speed > minimum
speed
Actual current ≥ current threshold
value
Absolute actual speed > speed
threshold value 2
Absolute actual speed < speed
threshold value 2
Speed setpoint reached
Actual DC link voltage ≦ threshold
value
Actual DC link voltage > threshold
value
tive.
Technology controller output ≦
p2292
Technology controller out‐
put > p2291
Advanced commissioning
Signal intercon‐
nection in the
converter
p2051[3] = r0053
141