DSTREAM-XT Getting Started Guide
To obtain optional adapters,
Indicator LEDs on the top
When you power up the DSTREAM-ST unit, the LEDs on top of the unit indicate the status of the
unit.
Figure 2-17: Indicator LEDs
DSTREAM logo
The DSTREAM logo on the top of the unit illuminates and the STATUS LED begins to flash
when you power up the DSTREAM-ST unit. The DSTREAM logo also flashes when you
click the Identify button in the
Firmware Installer view
STATUS
Illuminates green to show that DSTREAM-ST is in its ready state.
If a critical error is detected, the STATUS LED illuminates as continuous red. If the STATUS
LED is red, then you must reset the DSTREAM-ST unit to the factory settings before you can
continue using it. If the DSTREAM-ST unit fails to boot after a reset,
For more information, see
FLASH
Illuminates when the unit is accessing its internal flash storage.
TARGET
Illuminates when a valid target VTREF is detected.
DEBUG
Illuminates when debug data transfer takes place.