5.2 DSTREAM-XT overheats

The air intakes on the top of both the DSTREAM-ST unit and XT probe must remain clear of any
obstructions.
Air intakes are blocked
If the air intake on the top of the DSTREAM-ST unit becomes blocked and the DSTREAM-ST unit
overheats, it shuts down, all the LEDs turn off, and it remains in a safe state.
If the air intake on the top of the XT probe becomes blocked and the XT probe overheats, it enters
a low-power mode and its Status, Host Link, and Full LEDs flash red.
Solution
Check that the air intakes are clear, and then press Reset on the rear of the DSTREAM-ST unit to
reinitialize the DSTREAM-XT system.

5.3 Restore a DSTREAM-XT system

Use the recovery mode in DSTREAM-ST to restore your DSTREAM-XT system back to its factory
settings. If the other troubleshooting steps did not help, the recovery mode is useful to recover
your DSTREAM-XT system.
Before you begin
• Connect and power-up the DSTREAM-XT system. For more information on how to connect
and power-up the DSTREAM-XT system, see
• Attempt a soft reset of your DSTREAM-XT system, by pressing the Reset button on the rear of
the DSTREAM-ST unit, before running a full restore of the system.
• Debug hardware drivers are provided with Arm
Arm Development Studio installed on your host computer to access the drivers. For more
information on installing Arm Development Studio, see the
Started
Guide.
Procedure
1. Press and hold the reset button on the DSTREAM-ST unit for approximately 10 seconds.
2. When the STATUS LED flashes red, release the button.
The DSTREAM-ST unit erases the current firmware in its internal flash, and replaces it with the
original factory-installed version of the firmware.
When in recovery mode, debug and trace operations are disabled.
Copyright © 2021 Arm Limited (or its affiliates). All rights reserved.
Connect and power up the DSTREAM-XT system
Development Studio. You must have
®
Non-Confidential
Document ID: 102443_1.0_00_en
Arm Development Studio Getting
Version 1.0
Troubleshooting
Page 36 of 38

Advertisement

Table of Contents
loading

Table of Contents