Hose Assemblies - Bosch EPS 118 Original Instructions Manual

Injector tester
Hide thumbs Also See for EPS 118:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 47
5.4.9

Hose assemblies

!
When positioning the hose assemblies, e.g. on the
work surface, always ensure that the area is clean.
Every time before connecting the hose assembly to
the CRI/CRIN or piezo CRI, always make sure the
hose connections are clean.
i
All hose assemblies have a preinstalled strainer.
They collect contaminants which may appear du-
ring testing despite cleaning the CRI/CRIN or piezo
CRI. They are used in the hose assemblies for the
test oil return and the hose assembly for the injec-
tion chamber.
!
Change the strainer in regular intervals (see main-
tenance intervals in chapter 8.2.1). If the strainer
is not changed in time, it might break under incre-
asing dynamic pressure. Any dirt building up will
no longer be stopped from entering the system and
damaging components.
Hose assembly 1 684 462 570 and hose fitting
The hose assembly 1 684 462 570 (Fig. 9, item 1)
connect the injector return to the test connection for
the return quantity (see Fig. 3, item 3). Different hose
fittings are available for connecting the hose assembly
to different types of injectors (see Fig. 9). These are
inserted into the hose assembly before connecting to
the injector.
For certain CRIN from Bosch, the "CRIN adapter with
check valve" (Fig. 9, item 9) must be used as well.
It is inserted into the test connection for the return
quantity (CRI/CRIN, piezo CRI; see Fig. 3, item 3) prior
to starting the test and then connected to the hose
assembly 1 684 462 570 (Fig. 9, item 1).
i
After the CRIN is selected, whether or not the
"CRIN adapter with check valve" (Fig. 9, item 9)
is needed for the test is displayed in the EPS 118
software.
!
If the "CRIN adapter with check valve"
(Fig. 9, item 9) is not used in accordance with
the instructions or is connected incorrectly (e. g.
directly to the CRIN), a faulty measurement results,
leading to an incorrect evaluation of the CRIN.
Robert Bosch GmbH
Product description | EPS 118 | 63
2
3
4
5
6
7
Fig. 9:
Hose assembly 1 684 462 570 and hose fitting
1 Hose assembly 1 684 462 570
2 Bosch CRI hose fitting 1 681 334 034
3 Bosch CRI 2.5 hose fitting 1 681 032 119
4 Bosch CRIN hose fitting 1 683 386 192
5 Denso hose fitting 1 681 334 038
6 CRIN/Denso hose fitting 1 681 334 036
7 Delphi hose fitting 1 681 334 037
8 Strainer
9 CRIN adapter with check valve 1 683 350 904 for Bosch injec-
tors
Included in the non-Bosch CRI accessory set 1 687 010 718
1)
(optional accessories).
i
With injectors that have a locking clamp, secure
the hose assembly 1 684 462 570 with the locking
clamp.
Hose assembly 1 684 462 569
The hose assembly 1 684 462 569 connects the Bosch
piezo CRI test oil return to the return quantity test
connection (Fig. 3, item 3).
Fig. 10:
Hose assembly 1 684 462 569
en
1
8
458900-01_Pal
9
1)
with thread M8x1
1)
1)
458900-02_Pal
|
1 689 989 300
2020-03-24

Advertisement

Table of Contents
loading

Table of Contents