Weight 0 986 610; Base Plate 0 986 610; Adapter Set 0 986 610; Hydraulic Hose Assemblies - Bosch Denoxtronic 1.1 Product Description

Test device adblue supply module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
3.12
Weight 0 986 610 839
The weight (fig. 11, item 1) is used to calibrate the
scale 0 986 610 838.
i
Always keep the weight in a closed container
(fig. 11, item 2) to protect it from damage before
and after use.
i
Have the weight checked every two years by a recog-
nized workshop.
Fig. 11:
Weight 0 986 610 839
1 Weight 500g +/- 0.8 mg (class M)
2 2- part container (the bottom part is shown)
i
Detailed instructions on calibration can be found in
the operating instructions for the scale.
3.13

Base plate 0 986 610 837

The base plate 0 986 610 837 is used to hold dosing
modules of type Denoxtronic 1.1, for disassembly /
assembly. The assembly mandrels 0 986 610 836 and
0 986 610 846 are needed for disassembly / assembly
of the dosing module mixing chamber.
The parts set 0 986 613 847 is used for leak checking
the dosing modules.
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 1.1.
3.14

Adapter set 0 986 610 724

i
The adapters are need for leak checking the
air circuit of AdBlue delivery modules of type
Denoxtronic 1.1. The delivery module is connected
to the gas manifold using the adapters and supply
lines 0 986 610 926 and 0 986 610 927.
Robert Bosch GmbH
Devices and components | Denoxtronic 1.1 | 25
3.15

Hydraulic hose assemblies

Hydraulic hose assemblies are needed for various func-
tion tests, when troubleshooting and when purging the
AdBlue delivery module.
i
All of the hose lines must be handled carefully and
checked before use. Replace hoses if inspection
reveals the following damage: Cracks, brittleness,
abrasion, kinks, or sluggish or damaged quick-re-
lease couplings.
!
Defective hose lines must be completely replaced to
prevent damage and injury.
i
The proper way to connect and use the hose lines is
described in the ESI [tronic] test and repair instruc-
tions.
3.16
Instructions concerning initial com-
missioning
i
Apply the provided stickers to the test device
0 986 613 880.
Fig. 12:
Test device with stickers
1 Sticker 1 681 103 503 (Follow operating instructions)
2 Sticker´1 681 102 623 (Composition of the calibrating gas)
1. Affix the sticker "Follow operating instructions" to
the front of the test device (fig. 12, item 1). Remove
any grease from the surface to be used.
2. Affix the sticker "Composition of the calibrating gas"
to the side of the test device near the test gas con-
tainer (fig. 12, item 2). Remove any grease from the
surface to be used.
en
|
1 689 989 403
2019-03-01