Digital Inputs; Analogue Resistive Sensor Inputs - Deif SGC 410 User Manual

Single genset controller
Table of Contents

Advertisement

3.6 Digital inputs

Category
Controller terminals
Number of inputs
Type
Software configurable options

3.7 Analogue resistive sensor inputs

Category
Controller terminals
Number of inputs
Type
Range
Open circuit detection
Measurement accuracy
SCP connection
SCP connections for Analogue inputs 1 to 4*:
Analogue
resistive
sensor
Engine body
*SCP connections for Analogue input 2 used as Fuel level sensor with the reference configured as Battery Negative
Analogue
resistive
sensor
USER MANUAL 4189341243A UK
Sensor
input
T erminal 16
Sensor
common
SGC 4xx series
Sensor
input
Sensor
common
SGC 4xx series
Specifications
33, 34, 35, 36, 37, 38, 39, 40, 41
9
Negative sensing (connect to ground for activation)
Emergency stop, Remote start/ stop, and more (see Controller overview,
Configurable parameters in the User manual for more details).
Specifications
11 (Oil pressure)
12 (Fuel)
13 (Temperature)
14 (Aux 1)
15 (Aux 2)
5
Ratio-metric sensing
10 to 5000 Ω
Above 5.5 kΩ
±2 % of full scale (up to 1000 Ω)
Terminal 2
Supply
Terminal 1
Terminal 2
Supply
Terminal 1
Battery
Battery
Page 10 of 78