VAT 650 Series Installation, Operating, & Maintenance Instructions page 69

Pendulum control & isolation valve with cc-link interface with valve cluster functionality
Table of Contents

Advertisement

EXTENDED WARNING bitmap table:
Bit
REMOTE CONTROL NOT
0
POSSIBLE
ACTUAL CONTROL
1
MODE SETPOINT NOT
ALLOWED
2
ZERO DISABLED
3
PFO DEACTIVATED
4
NOT USED (reserved)
OUT OF RANGE:
5
PRESSURE SETPOINT
OUT OF RANGE:
6
POSITION SETPOINT
7-9
NOT USED (reserved)
OUT OF RANGE:
10
CONTROL MODE
SETPOINT
OUT OF RANGE:
11
GENERAL CONTROL
SETPOINT
PROCESS DATA
12
SETTING(S) NOT VALID
13-15
NOT USED (reserved)
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Remote control not possible, access mode local is active, change to acces mode remote or
access mode locked
Not possible to switch the actual control mode to CONTROL MODE SETPOINT
(for example control mode is interlock or fatal error)
Using zero function not possible
Power Failure Option is deactivated
-
Value of PRESSURE SETPOINT is out of range
Value of POSITION SETPOINT is out of range
-
Value of CONTROL MODE SETPOINT is out of range
Value of GENERAL CONTROL SETPOINT is out of range
Value of PROCESS DATA SETTING(S) not valid
(DATA TYPE or RANGE of pressure and position signals)
-