Signal
Name
Type
CLUSTER VALVE
Signal
FREEZE ADDRESS
SETPOINT
CLUSTER VALVE
Bitmap
FREEZE CONTROL
SETPOINT
CLUSTER VALVE
Signal
MONITORING ADDRESS
SETPOINT
1)
To adjust range refer to chapter: «Range of pressure and position values»
GENERAL CONTROL SETPOINT bitmap table:
Bit
0
ZERO
1
NOT USED (reserved)
2
PING PONG TX BIT
3
NOT USED (reserved)
4
ACCESS MODE LOCKED
5-7
NOT USED (reserved)
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Start
Byte
Word
Length
18
1
unsigned integer
19
1
boolean array
20
1
unsigned integer
0 = No Operation
1 = ZERO adjust, the actual pressure signal is set to internal pressure 0. The valid range for
adjustment is limited to -1.4V...+1.4! Otherwise the sensor must be adjusted!
-
PING PONG TX BIT transmitted from the master (PLC), is used to check the loop "master PLC -
VAT station". See chapter: 3.11.9
(PLC) and Station (Valve)
-
Note: Access mode switching, only in remote mode possible (Host PLC).
Start mode
local
locked
remote
-
Valid
Data Type
Range
0..254
0..254
Description
Communication and timing control between Master
Access mode locked bit
Set bit:
0 1
Reset bit: 1 0
Set bit:
0 1
Description
Select a valve that should be frozen.
0 : master
1.. 254 : slave
Note: Only valid if bit FREEZE DATA
VALID is set
See bitmap table below
Select a valve that should be
monitored.
0 : master
1..254 : slave
End mode
locked
remote
locked
280672EB
63/94
2010-12-15