VAT 650 Series Installation, Operating, & Maintenance Instructions page 67

Pendulum control & isolation valve with cc-link interface with valve cluster functionality
Table of Contents

Advertisement

Signal
Name
Type
Signal
FATAL ERROR
Bitmap
GENERAL STATUS
Bitmap
GENERAL WARNING
Bitmap
EXTENDED WARNING
CLUSTER VALVE
Signal
MONITORING
ADDRESS
CLUSTER VALVE
Signal
POSITION
CLUSTER VALVE
Signal
CONTROL MODE
CLUSTER VALVE
Bitmap
STATUS
CLUSTER VALVE
Bitmap
WARNINGS
1) To adjust range refer to chapter: «Range of pressure and position values»
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Start
Byte
Data
Word
Length
Type
unsigned
11
1
integer
boolean
16
2
array
boolean
17
2
array
boolean
18
2
array
unsigned
19
1
integer
signed
integer
20
4
(default) or
floating point
unsigned
22
1
integer
boolean
23
1
array
boolean
24
1
array
Valid
Range
20 = no stop detected during synch
mode
21 = valve blocked during synch mode
20,21,22,25,40
22 = valve blocked
25 = step loss during synch mode
40 = motor driver fault
See bitmap table below
See bitmap table below
See bitmap table below
Actual address of the selected cluster
0...254
valve.
0...100'000
Actual position of the selected cluster
(default),
valve.
1)
adjustable
0 = init
1 = synch
2 = position
3 = close
4 = open
5 = pressure
6 = hold
0...14
7 = learn
8 = interlock open
9 = interlock close
10 = maintenance open
11 = maintenance close
12 = power failure
13 = safety
14 = fatal error
See bitmap table below
See bitmap table below
280672EB
2010-12-15