5.
Range of pressure and position values (optional)
The «range of pressure and position values» can be adjusted. That means:
For position values, the value for valve position "CLOSE" and the valve position "OPEN" can be set to a
other ones then the default 0...100'000 is.
For pressure values, the value for physical 0 Volt and 10 Volt of the sensor output can be set to other values
then the default 0...1'000'000 is.
The range of pressure and position values can be configured by 'Control View', 'Control Performance Analyzer' or
'Universal Hyper Terminal'.
The «set-command» is: «s:24xxytoz».
y: lower scale value, floating point, entry with a point '.' and '-' for negative values possible
z: upper scale value, floating point, entry with a point '.' and '-' for negative values possible
xx: signal number in the buffer
xx
Value
00
Pressure
01
Not used – reserved
02
Not used – reserved
03
Position
04
Not used – reserved
05
Cluster valve position
06
Pressure setpoint
07
Position setpoint
08
Not used – reserved
09
Not used – reserved
10
Not used – reserved
Cluster valve freeze position
11
setpoint
The «get-command» is: «i:24xx». The answer returns the range
the current lower scale value of buffer and value z the upper scale value.
The format of y and z has following syntax: _ _ _ _ _ _ _ _._ _ _ _ _
Examples:
i:2400-0012345.12345to00123456.12345
i:2401-0001000.00000to00001000.00000
i:240200001000.00000to00001500.00000
Example «get-command» with Terminal: Get the range of Pressure Sensor 1:
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Default lower
scale value
0
-
-
0
-
0
0
0
-
-
-
0
Default range
Default
upper scale
value
1'000'000
-
-
100'000
-
100'000
1'000'000
100'000
-
-
-
100'000
«i:24xxytoz». The xx is the value number, y value is
Min/Max range
Min lower
Max upper
scale vlaue
scale value
-1'000'000
1'000'000
-
-
-
-
-1'000'000
1'000'000
-
-
-1'000'000
1'000'000
-1'000'000
1'000'000
-1'000'000
1'000'000
-
-
-
-
-
-
-1'000'000
1'000'000
280672EB
44/94
2010-12-15

Hide quick links: