VAT 650 Series Installation, Operating, & Maintenance Instructions page 62

Pendulum control & isolation valve with cc-link interface with valve cluster functionality
Table of Contents

Advertisement

3.11.7.2
Details
The commands are in view from customer CC-Link network to the valve.
Data format: All signals are transmitted and received in intel format (low byte first).
All one-byte signals use the least significant byte (LSB).
Signal
Name
Type
Signal
PRESSURE SETPOINT
Signal
POSITION SETPOINT
CONTROL MODE
Signal
SETPOINT
GENERAL CONTROL
Bitmap
SETPOINT
CLUSTER VALVE
Signal
FREEZE POSITION
SETPOINT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Start
Byte
Word
Length
signed integer
0
4
signed integer
2
4
10
1
unsigned integer
11
1
boolean array
signed integer
16
4
Valid
Data Type
Range
0..1'000'000
(default) or
(default),
floating point
adjustable
0..100'000
(default) or
(default),
floating point
adjustable
2...7
0..100'000
(default) or
(default),
floating point
adjustable
Description
In case of the valve is is pressure
mode (CONTROL MODE = Pressure
(5)), the signal is used as setpoint
1)
value.
In case of the valve is is position
mode (CONTROL MODE = Position
(2)), the signal is used as setpoint
value.
min signal value (default 0) = "valve is
closed"
max signal value (default 100'000) =
1)
"valve is opened"
Note: If you want to close the valve
completely, set bit CONTROL MODE
SETPOINT = 3 (Close) (only 650)
2 = Position: Position control mode
3 = Close: The valve is closed
4 = Open: The valve is opened
5 = Pressure: Pressure control mode
6 = Hold: Valve is kept in current
position; only valid in CONTROL
MODE position and pressure
7 = Learn: Valve starts the internal
learn procedure
See bitmap table below
Select the position of the valve that
should be frozen.
min signal value (default 0) = "valve
is closed"
max signal value (default 100'000) =
"valve is opened"
Note: If you want to close the valve
1)
completely, set bit FREEZE
CONTROL MODE = 1 (Close) (only
650)
Note: Only valid if bit FREEZE DATA
VALID is set
280672EB
62/94
2010-12-15