2.
Transmission rate
Use the same «transmission rate» for all stations in the bus and also for master station. If any of the settings for
at least one station is different, data link cannot be established normally.
The «transmission rate» can select from 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps
The «transmission rate» can be configured by 'Control View', 'Control Performance Analyzer', 'Universal Hyper Terminal'
or 'Service Box 2'.
The «set-command» is: «s:21xxx00000». The xxx value is the «transmission rate» shown in the table below
The «get-command» is: «i:21». The answer returns the «transmission rate»
current «transmission rate».
Consider that the controller must be in local mode to accept the commands! After a s:21 command is sent the module is
reseted and starts up again.
«c:0100»
change into local mode
«c:0101»
change into remote mode
Value
000
001
002
003
004
3.
Operational settings mode
The «operational settings mode» defines the following CC-Link parameters:
CC-Link version
Number of occupied stations: The number of stations (occupying one stations worth of memory area) used
by a single slave station in a network.
Extended cyclic settings: In the extended cyclic transmission (only Ver.2), the extended cyclic points can be
set as 2 times, 4 times or 8 times of the normal cyclic transmission points.
The VAT slave supports two combinations of the CC-Link parameter settings.
Value
Operational settings
001
CC-Link Ver.2 / Occupies 1 station / Octuple expanded cyclic
004
CC-Link Ver.2 / Occupies 4 stations / Double expanded cyclic
The «operational settings mode» can be configured by 'Control View', 'Control Performance Analyzer', 'Universal Hyper
Terminal' or 'Service Box 2'.
The «set-command» is: «s:22xxx00000». The xxx value is the operational settings mode!
The «get-command» is: «i:22». The answer returns the «operational settings mode»
the current operational settings mode.
Consider that the controller must be in local mode to accept the commands! After a s:22 command is sent the module is
reseted and starts up again.
«c:0100»
change into local mode
«c:0101»
change into remote mode
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
Transmission rate
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps
«i:21xxx00000». The xxx value is the
«i:22xxx00000». The xxx value is
280672EB
2010-12-15
42/94