Parameter
Default Value Description
Initial setup parameters, found at:
Dealer Menu > Initial Setup > Adaptive Dial Controller > Holeshot
Planing Boat
22 mph
Speed
Min Boat
3000 rpm
Planing RPM
Deploy
Position
Deploy Hold
Duration
Retract to
Favorite
Speed
Min Deploy
2000 rpm
RPM
Settings parameters, found at:
Dealer Menu > Settings > Adaptive Dial Controller > Holeshot
Planing Time
15.0 sec
Limit
Table 6-4.
40
The minimum speed-over-ground (SOG) at which
the boat gets on plane under slow acceleration.
This parameter is only used if a SOG source is
available and the SOG feature is enabled (table 6-5).
The lowest engine RPM at which the boat gets
on plane under slow acceleration with all engines
deployed and trimmed in their normal running
position.
100%
The position of the tabs when deployed for a hole-
shot, where 0% is fully retracted and 100% is fully
extended.
3.0 sec
The time that the deploy position is held before
tabs begin to retract. This parameter is not used if
an SOG source is available and the SOG feature is
enabled (table 6-5).
3.0 sec
The time it takes to go from the holeshot deployed
position to the adaptive cruising favorite position.
The RPM that triggers tab deployment when
Holeshot Mode is activated.
The user has this amount of time to initiate a holeshot
once Holeshot Mode is activated. If the time expires,
Holeshot Mode will be deactivated and the tabs will
retract to the adaptive cruising favorite position. This
parameter is not used if an SOG source is available
and the SOG feature is enabled (table 6-5).