Weighing system
-
The weight indication in bucket is cal-
culated by measuring boom position
and boom pressure.
1.
The weight is '0.0 ton' when the
boom is placed at below -15°.
2.
The weight is indicated when the
boom is placed at the range
(-5°→15°).
3.
The weight is calculated when the
boom is placed at above -5° and
boom is lowered below -15° after
dumping operation.
In order to recheck weight, go to
the ⓑ after changing boom posi-
tion (below -15°).
-
Dump operation : It is checked by buck-
et cylinder's stroke change (below 250
mm).
The temperature for the hydraulic oil must be raised to at least 40 °C (104 °F) before opera-
tion.
Boom/bucket detent mode
·
OFF
·
ON
·
Save position: Refer to page 4-20.
Bucket priority mode (option)
•
The bucket priority function is more convenient for the operator to load materials.
: Detent functions are not operated.
: Boom or bucket detent functions are operated.
3-26