(9) Fill the engine with clean oil to the proper level.
Quantity: 11 ℓ (2.9 U.S. gallons)
(10) Operate the engine at low idle and inspect for
leaks at the filter and the drain plug.
Shut the engine off and the check oil level with
dipstick. Allow 15 minutes for the oil to drain
down before checking.
Do not overfill the engine with oil.
3) CHECK COOLANT LEVEL
(1) Check the engine fault code on the monitor.
(2) If the following fault codes exist, check the cool-
ant level.
• SPN: 111, FMI: 18
- Coolant level is low.
• SPN: 111, FMI: 1
- Coolant level is the most severely low.
(3) Add the mixture of antifreeze and water after re-
moving the cap of the surge tank if coolant is
not sufficient.
Oil
Cap
Sight
gauge
6-16
F u
e l
NOT OK
Surge tank
t a n
k

Hide quick links: