(19) Connect the breather tube connection to the
rocker lever cover.
In general, two types of breather tube connec-
tions are used at the rocker lever cover.
•
A clamping plate and capscrew hole the
breather tube connection to the rocker lev-
er cover. Remove the capscrew and
clamping plate to disconnect the breather
tube connection from the rocker lever cov-
er.
•
One or two capscrew(s) directly mount the
breather tube connection to the rocker lev-
er cover. Remove the capscrew(s) to dis-
connect the breather tube connection from the rocker lever cover.
(20) Tighten the capscrew(s).
Tightening torque : 1.0 kgf·m (7.2 lbf·ft)
22) HYDRAULIC OIL LEVEL CHECK
(1) Lower the bucket to the ground at a flat location
as in the illustration.
Stop the engine and then leave for about 5 mi-
nutes.
(2) Check the oil level using the sight gauge. The
sight gauge is located on the left side of the hy-
draulic oil tank.
(3) The sight gauge should indicate the middle po-
sition.
Add hydraulic oil, if necessary.
6-37
Sight gauge