Cable Configuration For The Ups; Establishing A Telnet Connection - Cabletron Systems EMME User Manual

Ethernet management module with ethernet
Table of Contents

Advertisement

CHAPTER 5: LOCAL MANAGEMENT
5.1.2 Cable Configuration for the UPS
To configure a cable from the Uninterruptible Power Supply (UPS) to the
EMME perform the following steps:
1. Plug a straight-through twisted pair, RS232, cable into the EMME
RJ45 Modem port.
2. Plug the other end of the RS232 cable into the adapter (Part No.
9372066) and connect the adapter to the UPS.
After the cable configuration is complete, use one of the following
management tools to configure the EMME Modem port for UPS
application:
EMME Local Management – The System Level Screen section of this
chapter provides instructions for setting up the EMME Modem port
for the UPS application.
Graphical user interfaces provided by SPECTRUM Element Manager
for Windows, SPECTRUM Portable Management Applications
(SPMAs), or SPECTRUM software packages.
5.2

ESTABLISHING A TELNET CONNECTION

Once the EMME has a valid IP address, you can establish a Telnet session
with Local Management from any TCP/IP based node on the network.
Telnet connections to the EMME require the community name passwords
assigned at the SNMP Community Names screen. Refer to the SNMP
Community Names section of this manual for additional information
about community names.
See the instructions included with the Telnet application for
NOTE
information about establishing a Telnet session.
Page 5-4
EMME USER'S GUIDE

Advertisement

Table of Contents
loading

Table of Contents