Cabletron Systems SWPIM-T1 Installation Manual

Enterasys swpim-t1 interface module: install guide

Advertisement

Quick Links

SWPIM-T1
Title Page
Installation Guide
LNK
STS
SWPIM-T1
9033058-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWPIM-T1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cabletron Systems SWPIM-T1

  • Page 1 SWPIM-T1 Title Page Installation Guide SWPIM-T1 9033058-01...
  • Page 3: Fcc Notice

    WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. SWPIM-T1 Installation Guide NOTICE FCC NOTICE...
  • Page 4: Industry Canada Notice

    This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. SWPIM-T1 Installation Guide...
  • Page 5: Program License Agreement

    If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. SWPIM-T1 Installation Guide Notice...
  • Page 6 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. SWPIM-T1 Installation Guide...
  • Page 7 If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. SWPIM-T1 Installation Guide Notice...
  • Page 8 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. SWPIM-T1 Installation Guide...
  • Page 9 If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. SWPIM-T1 Installation Guide Notice...
  • Page 10 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. viii SWPIM-T1 Installation Guide...
  • Page 11: Declaration Of Conformity

    Mr. Ronald Fotino ___________________________________ Full Name Compliance Engineering Manager ___________________________________ Title Rochester, NH, USA ___________________________________ Location SWPIM-T1 Installation Guide 89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J. Solari Cabletron Systems Limited Nexus House, Newbury Business Park...
  • Page 12 Notice SWPIM-T1 Installation Guide...
  • Page 13: Table Of Contents

    SWPIM-T1 Features... xiv Related Manuals...xv Document Conventions ... xvi Getting Help... xvii CHAPTER 1 INSTALLATION Unpacking the SWPIM-T1 ... 1-1 Installing the SWPIM-T1... 1-2 LANVIEW LED Indications ... 1-4 Connecting to the Network ... 1-5 Completing the Installation ... 1-5 APPENDIX A SPECIFICATIONS Physical Properties...A-1...
  • Page 14 Contents SWPIM-T1 Installation Guide...
  • Page 15: Introduction

    SWPIM-T1, lists features and capabilities, details the cabling pinouts, and explains how to install the SWPIM-T1. The SWPIM-T1 provides a full and a fractional T1 interface for a host platform designed to receive the SWPIM (Sliding WAN Physical Interface Module) architecture.
  • Page 16: Swpim-T1 Features

    Refer to the host platform software user’s manual for information on how to configure the SWPIM-T1 using software. The SWPIM-T1 uses a single RJ48 connector supporting the T1 interface. Refer to Appendix A for the Cabletron Systems part number and pin assignments for the T1 interface cable.
  • Page 17: Related Manuals

    • Supports FDL Circuitry • Channelized Loopback Capability LEDs The SWPIM-T1 has two LEDs, which indicate link and status conditions. Refer to Chapter 1 for more details. RELATED MANUALS The following Cabletron Systems manuals may help the user to set up and...
  • Page 18: Document Conventions

    Tip symbol. Conveys helpful hints concerning procedures or actions. Caution symbol. Contains information essential to avoid damage to the equipment. CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard. SWPIM-T1 Installation Guide...
  • Page 19: Getting Help

    Network load and frame size at the time of trouble (if known) • The device history (i.e., have you returned the device before, is this a recurring problem, etc.) • Any previous Return Material Authorization (RMA) numbers SWPIM-T1 Installation Guide http://www.cabletron.com/ (603) 332-9400 support@cabletron.com ftp://ftp.cabletron.com/ anonymous...
  • Page 20 Introduction xviii SWPIM-T1 Installation Guide...
  • Page 21: Chapter 1 Installation

    Failure to observe static safety precautions could cause damage to the SWPIM-T1. Follow static safety handling rules CAUTION and wear the antistatic wrist strap shipped with the SWPIM-T1. Do not cut the non-conductive bag to remove the device. Damage could result from sharp objects contacting the device or components.
  • Page 22: Installing The Swpim-T1

    Chapter 1: Installation INSTALLING THE SWPIM-T1 The SWPIM-T1 can be installed in any available open slot in the host platform. To install the SWPIM-T1, proceed as follows: You do not need to power down the host platform to install the SWPIM-T1.
  • Page 23 The SWPIM-T1 must be configured before the WAN connection is made. Once the SWPIM-T1 has been configured, the host platform must undergo a soft or hard restart in order for the SWPIM-T1 to be recognized and for traffic to pass. Refer to the appropriate software manual to configure the SWPIM-T1.
  • Page 24: Lanview Led Indications

    Chapter 1: Installation LANVIEW LED INDICATIONS Refer to Table 1-1 for the link LED indications for the SWPIM-T1. Color Amber Green Blinking Green Refer to Table 1-2 for the status LED indications for the SWPIM-T1. Color Amber Blinking Amber Blinking Green...
  • Page 25: Connecting To The Network

    SSR-600 Figure 1-2 SWPIM-T1 Typical Configuration COMPLETING THE INSTALLATION After installation, the SWPIM-T1 will need to be configured for the network. Refer to the host platform software documentation in order to set up and manage the SWPIM-T1. SWPIM-T1 Installation Guide...
  • Page 26 Chapter 1: Installation SWPIM-T1 Installation Guide...
  • Page 27: Appendix Aspecifications

    This section describes the environmental specifications and safety and approval requirements for the SWPIM-T1. Cabletron Systems reserves the right to change these specifications at any time without notice. Pinouts and the T1 cable are also listed in this appendix. PHYSICAL PROPERTIES...
  • Page 28: Pinout For The T1 Interface Connector

    Table A-1 Pinouts for the T1 Interface Connection T1 CABLE ASSEMBLY Table A-2 lists Cabletron Systems part numbers for the interface cables for the SWPIM-T1. A standard 20-foot cable is available or the customer may specify the length of cable when ordering. Table A-2 Interface Cable...
  • Page 29: Environmental Requirements

    The following table provides connector information for the SWPIM-T1 interface cable. Table A-3 SWPIM-T1 Connector Information Cabletron Systems interface cable part number Description Connector 1 Connector 2 ENVIRONMENTAL REQUIREMENTS Operating Temperature: Non-operating Temperature: Operating Humidity: REGULATORY COMPLIANCE Safety Electromagnetic Compatibility (EMC)
  • Page 30 Appendix A: Specifications SWPIM-T1 Installation Guide...
  • Page 31: Fcc Part 68 - User's Information

    You will be advised of your right to file a complaint with the FCC. SWPIM-T1 Installation Guide APPENDIX B REN/SOC 6.0N...
  • Page 32: Appendix Bfcc Part 68 - User's Information

    Company or to one of our authorized agents. Service can be obtained at Cabletron Systems Technical Support: Address: Phone: Internet mail: Cabletron Systems, Inc. 35 Industrial Way Rochester, NH 03867-0505 (603) 332-9400 support@ctron.com SWPIM-T1 Installation Guide...
  • Page 33 • The encoded analog and billing protection is factory set and is not under the control of the customer. SWPIM-T1 Installation Guide Appendix B: FCC Part 68 - User’s Information , of (Customer Name) (Telephone Number) Subrate digital services.
  • Page 34 Subscribed and sworn to me this (Notary Public) My commission expires: above. (Telco’s Name) SWPIM-T1 Installation Guide with proper documentation (Signature) (Title) (Date) day of , 19...