<Command Entry Example>
An example of executing the command to show the link aggregation
configuration is shown below.
M24eGi> enable
M24eGi# show aggregation-link group
Aggregation Group <1>
(1)
Status
: Static
(2)
Criterion
: src-dst-mac / src-dst-ip / src-dst-L4-port
(3)
Admin Ports : gi0/9-10
(4)
Oper Ports : gi0/9-10
(5)
Aggregation Group <2>
Status
: Static
Criterion
: src-dst-mac / src-dst-ip / src-dst-L4-port
Admin Ports : gi0/20-24
Oper Ports : (none)
M24eGi#
Fig. 4-2-1 Example of executing the command to show the link aggregation
(1) Aggregation Group <1-8>
Shows the aggregation group ID.
(2) Status
Shows the aggregation group configuration status.
Static
(3) Criterion
Shows the traffic distribution type.
src-dst-mac
src-
dst-ip
src-dst-L4-
port
(4) Admin Ports
Shows the list of ports set in the aggregation group.
(5) Oper Ports
Shows the list of ports currently belonging to the aggregation group.
Shows "(none)" if none of the Admin Ports are linked up.
configuration
Indicates that the aggregation link is statically
registered.
Traffic distribution is performed based on the
destination and the source MAC address, IP
address and L4 port value of the transmitted
frame.
202