Table 13. Console Configuration Settings - Cabletron Systems SmartStack STS16-20R Installation And User Manual

Cabletron systems user guide token ring switches sts16-20d, sts16-20r
Hide thumbs Also See for SmartStack STS16-20R:
Table of Contents

Advertisement

3. Use the values listed in the following table to set the configuration parameters
on your console for interfacing to the SmartStack STS16-20D/STS16-20R.
Specification
Baud Rate
Parity
Data bits
Stop bits
Handshaking
Terminal emulation
Duplex
Software flow control
(XON/XOFF)
Hardware flow
control (RTS/CTS)
Autobaud upon break
Line wrap
Screen scroll
CR translation
Backspace (BS)
translation
Break length
(milliseconds)
Enquiry (ENQ)
EGA/VGA true
underline
Terminal width
ANSI 7 or 8 bit
commands

Table 13. Console Configuration Settings

Accessing Switch Management
Value
2400, 4800, 9600, 19200, 38400, 57600
None
8
1
None
VT100
Full
Off (input and output)
Off
On
On
On
CR
Destructive
350
Off
Off
80
7
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
71

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartStack STS16-20R and is the answer not in the manual?

This manual is also suitable for:

Smartstack sts16-20d

Table of Contents

Save PDF