Formax Atlas C350 Operator's Manual page 78

Automatic air-feed programmable folder/creaser
Table of Contents

Advertisement

FO-301 - Jam between units B
Jam between units B occurs when it takes too long for a paper to cover the distance
between sensor Q7 and sensor Q40. This means that the paper got stuck between the
rollers.
Actions:
-See Section 4 - Jam in the Folder
-Check for misfeed sheets / debris under the sensor box (where Q7 is located)
-Lower FAN1 power
-Ensure that there are no obstructions in the paper path
3
FO-302 - Jam between units C
Jam between units C occurs when Q40 sensor is activated for too long. This means that
the paper got stuck between the rollers.
Actions:
-See Section 4 - Jam in the Folder
-Check input guides
-Check that creaser tools are in open position (see setting crease pressure)
-Ensure that there are no obstructions in the paper path
FO-305 - Fold 1 Sensor not covered in time
This error occurs when it takes too long for a paper to cover the distance between sensor
Q40 and sensor Q45.
Actions:
-See Section 4 - Jam in the Folder
-Check that creaser tools are in open position (see setting crease pressure)
-Ensure that there are no obstructions in the paper path
FO-306 - Fold 1 Sensor not uncovered in time
JAM 306 - Fold 1 Sensor not uncovered in time
This error occurs when the Q45 sensor is not uncovered in time.
Actions:
-See Section 4 - Jam in the Folder
-Check paper path in delivery module
-Ensure that there are no obstructions in the paper path
FO-309 - Folder 1 position error
JAM 309 - Folder 1 position error
This error occurs when the Q41 Blade drive 1 home sensor is not actuated in time during
run.
Actions:
-Remove misfed sheet(s)
-Ensure that there are no obstructions in the paper path
Continued on next page...