5.15.12 Changing the Com Port Application

After enabling the COM port as described in
select one of the applications supported by the COM port: LM, and UPS.
The default application is LM.
To change the COM port application:
1.
Use the arrows keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to step through the available
settings until the operation you require appears.
available settings and their corresponding applications.
Setting
LM
UPS
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight SAVE at the bottom of the screen, then
press the ENTER key.
5.
When the message "SAVED OK" appears, the edits you made are
saved.
When the COM port is configured to perform the UPS
!
application, all future Local Management connections must be
made by establishing a Telnet connection to the module.
CAUTION
Ensure that the module has a valid IP address before saving
changes to the COM port application. If the module does not
have a valid IP address and the changes are saved, refer to
Appendix C
reestablish COM port communications.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User's Guide
Table 5-3. COM Port Application Settings
Application
Local Management Session
APC Power Supply SNMP Proxy
for instructions on clearing NVRAM in order to
General Configuration Screen
Section
5.15.11, you can
Table 5-3
lists the
5-55