Push-Button Alarm; Test Alarm; Personal Alarm - ASCOM d81 User Manual

Dect handset
Hide thumbs Also See for d81:
Table of Contents

Advertisement

User Manual
Ascom d81 DECT Handset
If a shared phone is used, it must be logged in to the system to be able to send alarm. See
3.2 Log In or Out of a Shared Phone
NOTE: If two or more alert notifications of equal priority are generated, the one generated
first is displayed first.
CAUTION: Recognition of alerts, warnings, and conversation messages can be impeded if
the volume of the sounds used to indicate alerts, warnings, and conversation messages is
lower than the ambient sound levels.
Table 2 on page 50 shows the sound pressure levels for the alarms.
Table 1. Alarm sound pressure levels
Minimum
Maximum
6.1

Push-Button Alarm

The push-button
press. By default, long press is defined for test alarm (see
press is defined for personal alarm (see
6.1.1

Test Alarm

Press and hold the push-button
displayed. Depending on set parameters;
a beep is heard
the orange LED flashes twice
the vibrator stirs
the handset receives a notification that the alarm has been received by the system. This
is a system dependent feature.
if configured, the ALS (see
the alarm has been sent, or a call is established to a predefined number (see
Automatic Call after Alarm
NOTE: If the parameter "Silent alarm" is set, no ALS is triggered and no indication of an
alarm has been sent by the handset or received by the system is shown.
information about the handset's location is sent along with the alarm, see
Location Information
6.1.2

Personal Alarm

Press the push-button
displayed. Depending on set parameters;
a beep is heard
the orange LED flashes twice
the vibrator stirs
18 June 2018 / Ver. K
6 Alarm Operation
on page 23.
Medium priority alarm
(1 beep)
60.27 dB
81.47 dB
can be defined to send an alarm by a long press and by multiple
6.1.2 Personal
until a dialog window "Test Alarm" (default) is
6.5 Acoustic Location Signal
on page 50)
on page 49.
twice or more, the dialog window "Personal Alarm" (default) is
High priority alarm (siren)
61.09 dB
82.76 dB
6.1.1 Test
Alarm), and multiple
Alarm).
on page 50) is activated after
6.4 Alarm with
TD 92644EN
6.6
47

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the d81 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents