4.2.2. Installation of the Inorecip H (option)

Inorecip H must be installed on a flat floor with a
resistance of 40 daN/cm
WARNING : it is imperative to respect the mini-
mum distance of 350 mm between the Inorecip
V and the inside of the powder booth.
WARNING : The handling of the Inorecip V must
be done by at least two operators and the lifting
equipment must be adapted to the weight and
size of the robot.
Remove the two protective covers of the
Inorecip H with 4 M4 screws per cover.
Remove the 2 side covers of Inorecip V with 6 M4
screws per cover.
Remove the 4 wheels of the Inorecip V by remo-
ving the 4 M8 screws per wheel.
Index revision : A
2
.
Out of ex-
plosive
at-
mosphere
Inorecip V
Inorecip H
Side covers
4 M8 screws
17
Zone 22
1000
350 mini
Protective covers
Wheel
7140