6.4. Drive settings

For Inorecip V to work properly, check the settings indicated in the table below on the drive
located in the electrical box of the reciprocator.
Adjustment procedure of the drive:
• Step 1: Press key (D). "1-" is displayed on the
screen.
• Step 2: Press key (D) again. "1-00" is dis-
played on the screen.
• Step 3: Press key (D) again. "1-00" is dis-
played on the screen. This allows to access
to the parameter.
• Step 4: Press key (A). The value "75.0" is dis-
played for parameter 1-00.
• Step 5: Press key (D). "END" is displayed
momentarily. The setting is now saved. The
parameter is displayed on the screen
again.
• Step 6: Press key (A) to move to the next
parameter.
• Step 7: Press key (D) to set the next parame-
ter.
• Step 8: Repeat the procedure for each
parameter from Step 4.
• Step 9: After saving all parameters, press key (C) twice to return to the main menu.
Index revision : A
Settings
1-00
1-01
1-02
1-03
1-04
1-06
2-00
2-01
2 (Enabled during constant-speed operation and
6-02
6-03
6-04
7-00
7-01
7-02
8-00
8-02
9-02
9-04
Inorecip V Settings
75,0
75,0
230 V
50
230
10
4 (RS-485 communication interface)
2 (For external terminals,
the STOP keyboard is disabled
stopped after detection)
70
0.5
40
40
9
10
0.5
2 (Warning and stop ramp)
2 (Mode RTU / 8,N,2)
37
(A)
(B)
(C)
(D)
7140