Power Supply (Ps) Interconnect Cable - Lincoln Electric FineLine 12864 Operator's Manual

300hd plasma system
Table of Contents

Advertisement

FineLine 300HD Plasma System
Error
Status
Code
Light
10023
815
Cooler Level Fault
10025
825
Switchboard Thermistor Not
Connected
10026
751
Switchboard A Thermal Error
10027
752
Switchboard B Thermal Error
10029
64
Safety Circuit Not Ready
10030
299
N2 Over Pressure
10031
299
O2 Over Pressure
10032
299
H17 Over Pressure
10033
299
Air Over Pressure
10034
299
Argon Over Pressure
10037
492
Gas MUX Missing
10038
491
CAN Fault
10039
45
Secondary Over Voltage
10063
Other
Power Source Fault
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Power Supply Specific Errors
Description
Page 88 of 118
BK8053-000107 Rev A.01
Possible Resolution
5) Check the coolant filter cartridge
and replace if dirty.
1) Check for coolant leaking from
supply and return hoses, ASC, torch
leads, and torch connections.
2) Add coolant to the reservoir until
it reaches the bottom neck of the
reservoir.
Check that the thermistor is plugged
into each switchboard.
1) Check for blockage of the inlet
and outlet vents to the power
sections.
2) Check that power section fans
are operating properly.
EStop activated.
Adjust gas regulator until pressure
is within specifications. Refer to
Section 2.6.
Check wiring between control board
and gas mux PCB.
Check the Power Supply
interconnect cable.
Read the error conde blinking on
the front of the power supply and
report the fault to Lincoln Electric
service department for assistance.