Lincoln Electric FineLine 12864 Operator's Manual page 73

300hd plasma system
Table of Contents

Advertisement

BK8053-000107 Rev A.01
Mild Steel - 200 Amps - Oxygen Plasma / Air Shield
Shield Cap
BK602345
Outer Cap
BK602365
Imperial*
Material
Preflow
Thickness
(psi)
(in)
1/4
3/8
1/2
5/8
3/4
13
1
1.25
1.5**
1.75**
2**
Metric*
Material
Preflow
Plasma
Thickness
(psi)
(mm)
8
10
12
15
20
25
13
30
35**
40**
45**
50**
* Use an arc transfer height (ignition height) of .250" (6.4 mm) for cutting and .100" (2.5 mm) for marking.
** Edge start recommended.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Retaining Cap
BK602332
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
57
74
74
52
43
Shield
Postflow
(psi)
(psi)
(psi)
57
74
74
52
49
43
Page 73 of 118
FineLine 300HD Plasma System
Nozzle
BK602317
Swirl Ring
BK602359
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
125
230
0.080
131
145
0.100
135
120
0.115
138
100
0.130
142
75
0.150
143
50
0.175
155
30
0.200
165
20
0.275
176
14
0.325
188
7
0.350
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
128
4720
2.3
132
3588
2.6
134
3188
2.8
137
2680
3.2
142
1810
3.9
143
1310
4.4
152
902
4.9
160
632
6.1
168
462
7.4
177
340
8.3
186
200
8.8
Electrode
BK602304
Torch
BK602622
Pierce
Pierce
Height
Time
Width
(in)
(msec)
300
0.100
0.250
400
0.114
0.300
500
0.117
0.350
600
0.118
0.400
800
0.125
0.450
1100
0.136
0.500
1800
0.150
0.188
0.350
1500
0.205
0.222
Pierce
Pierce
Height
Time
Width
(mm)
(msec)
(mm)
6.4
352
6.5
415
7.3
478
8.5
572
10.4
845
11.4
1081
12.4
1607
8.9
1500
Kerf
(in)
Kerf
2.7
2.9
3.0
3.2
3.4
3.7
4.3
4.9
5.2