Appendix C PS Interconnect Cable Extender

For standard installations, the maximum length of the Power Supply (PS) Interface
Cable is 75 ft. (22.8m) due to CAN communication limits. For installations requiring
longer lengths, a PS Interconnect Cable Extender (BK300364) consisting of a CAN
Bridge can be used to extend the length. The Extender allows two standard PS
Interconnect Cables to be joined together, extending the distance between the
Power Supply and Gas Controller up to a maximum of 150 ft. (45.7m). Two
standard PS Interconnect Cables of any length can be used, but the maximum
length per cable is 75 ft. for a maximum combined length of 150 ft.
One PS Interconnect Cable is supplied standard with the System. One additional
PS Interconnect Cable is required to use the PS Interconnect Cable Extender.
PS Interconnect Cable #1
1) Connect one end of PS Interconnect Cable #1 to the connector labelled P1 on
the Power Supply. Connect the other end to either of the connectors on the
PS Interconnect Cable Extender.
PS Interconnect Cable #2
2) Connect one end of PS Interconnect Cable #2 to the open connector on the
PS Interconnect Cable Extender. Connect the other end to the connector
labelled P1 on the Gas Controller.
Power
Supply
P1
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
150 ft.
(45.7m)
Maximum
PS Interconnect
Cable Extender
PS Interconnect
Cable #1
Page 131 of 132
FineLine 300HD Plasma System
75 ft.
(22.8m)
Maximum
P1
PS Interconnect
Cable #2
GC
Input
Side