3.1.2 Automatic Gas Console (AGC)
The AGC must be mounted within 8 ft. (2.44m) of the torch. Secure the AGC to the
mounting surface using three ¼" or M6 bolts. Refer to the mounting pattern shown in
Section 2.7. Ensure the port on the side of the AGC marked "VENT" is not blocked.
The AGC is IP23 rated.
The plasma and shield hoses connecting the torch to the AGC run inside the torch
leads for 6 ft. (1.83m) before breaking out to connect to the AGC. As such, the AGC
has to be mounted within 2 ft. (0.61m) of the torch lead routing. To minimize high
frequency interference from the arc starting circuit, it is recommended that the AGC
be mounted as far as possible - 2 ft. (0.61m) - from the torch leads with the control
cables routed away from the torch leads. All control/communication cables must be
routed with a minimum separation of 2 ft. (0.61m) from the torch leads and a
minimum separation of 6 in. (152mm) from the power leads.
Ethernet
Router/Switch
Power Supply
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Control & Comms
6 in. (152mm)
MINIMUM
Power Leads
6 ft.
(1.83m)
Page 22 of 118
BK8053-000107 Rev A.01
ASC
Control &
Comms
MAXIMIZE
DISTANCE
Torch
Leads
2 ft.
(0.61m)
MINIMUM
Plasma
Shield
2 ft.
(0.61m)