Lincoln Electric FineLine 12864 Operator's Manual page 72

300hd plasma system
Table of Contents

Advertisement

FineLine 300HD Plasma System
Mild Steel - 140 Amps - Oxygen Plasma / Air Shield
Shield Cap
BK602343
Outer Cap
BK602365
Imperial*
Material
Preflow
Thickness
(psi)
(in)
10 Ga
3/16
1/4
5/16
3/8
1/2
15
5/8
3/4
1.00
1.25**
1.50**
Metric*
Material
Preflow
Plasma
Thickness
(psi)
(mm)
4
5
6
8
10
12
15
15
20
25
30**
35**
38**
* Use an arc transfer height (ignition height) of .200" (5.1 mm) for cutting and .100" (2.5 mm) for marking.
** Edge start recommended.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Retaining Cap
BK602339
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
64
71
71
55
45
36
Shield
Postflow
(psi)
(psi)
(psi)
64
55
71
71
54
46
45
40
36
Page 72 of 118
Nozzle
BK602315
Swirl Ring
BK602358
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
120
260
205
122
160
0.105
140
124
120
128
86
133
70
0.140
136
55
142
35
0.160
152
20
0.200
162
12
0.225
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
121
6011
5044
122
4318
2.7
124
3540
125
2919
127
2375
132
1890
3.3
137
1321
3.6
142
921
4.0
149
613
4.8
157
404
5.4
162
308
5.7
BK8053-000107 Rev A.01
Electrode
BK602309
Torch
BK602622
Pierce
Pierce
Height
Time
Width
(in)
(msec)
300
0.088
0.200
400
0.090
0.225
500
0.250
0.092
600
0.275
0.094
0.300
700
0.103
0.325
900
0.105
0.350
1100
0.110
1600
0.120
0.400
0.135
1500
0.158
Pierce
Pierce
Height
Time
Width
(mm)
(msec)
(mm)
5.1
342
5.2
414
5.6
478
6.4
600
7.1
615
7.5
678
8.1
845
9.1
1175
10.1
1569
10.2
1500
Kerf
(in)
Kerf
2.3
2.4
2.6
2.7
2.8
3.0
3.3
3.7
4.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents