Each plasma system component as well as any other related equipment (CNC,
motor drives, etc.) must have a separate ground connection to the star ground point
even if bolted to the gantry or Power Supply. Grounds are not to be daisy-chained.
For components mounted to the cutting table gantry, it is acceptable to create a star
ground at the gantry with a single ground cable connecting the gantry star ground
with the cutting table star ground.
Refer to Appendix A for additional information.
AC Power
Service GND
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
AGC
Gantry
Work
Lead
Power Supply
Protective
Earth
* If the CNC / HMI is mounted to the Gantry, the CNC / HMI
chassis ground should be connected to the Gantry Star GND.