A-7
POWER SOURCE TO LN-25™ PIPE
CABLE CONNECTION DIAGRAMS
CV Power Sources with Stud Connectors and
Remote/Local Switch (See Figure A.6)
CV-400
CV-655
DC-400
DC-600
DC-655
V450-Pro
SAE 400 with CV adapter
Engine Driven welder with
Wire Feed Module
Ranger 250 GXT
Place the power source Remote/Local switch in the
Local position.
Place CV/CC switch in the feeder in the "CV" position.
CV Power Sources with Stud Connectors and no
Remote/Local Switch. (See Figure A.7)
Place CV/CC switch in the feeder in the "CV" position.
Ranger 250, 250 LPG
Ranger 305G, 305D
Ranger 10,000
Ranger 3 Phase
Ranger 225GXT
Ranger 225
Commander 300
Vantage 300, 400, 500
Air Vantage 500
INSTALLATION
FIGURE A.6
Electrode
Work
See magnum Literature
FIGURE A.7
Jumper
Electrode
Work
See Magnum Literature
*If Power Source has a 14-Pin Cable connector and no
"Output Terminal" switch.
LN-25™ PIPE
LN™-25 PIPE
(Across the Arc)
Work clip
K#
K2614-5
KP1695-XX
KP1696-XX
KP1697-XX
CV power Source
K1803-1
LN™-25 PIPE
K#
K2614-5
K484*
KP1695-XX
KP1696-XX
KP1697-XX
CV power Source
K1803-1
A-7
Description
LN-25™ PIPE
Drive Roll Kit
Welding Gun
Welding Cables
Work clip
Description
LN-25™ PIPE
Jumper Plug Kit
Drive Roll Kit
Welding Gun
Welding Cables