BK8053-000107 Rev A.01

3.16 Software Installation

3.16.1 CutLinc Server
Installation and Commissioning
If the System uses a non-Lincoln Electric HMI (CNC Controller or Industrial
Computer), the CutLinc Server must be installed and commissioned. This is not
required when using a Lincoln Electric provided HMI.
Contact Factory for CutLinc Server Installer.
Manual Start
CutLinc server should automatically start each time the HMI is rebooted; however, to
manually start CutLinc Server, run file:
C: > Program Files > Lincoln Electric > CutLincServer > startCLServer.bat
Discovery for Single-Torch Systems
When any of the System's Ethernet adapters are replaced (e.g., Processor Engine
PCB in the AGC), the CutLinc server needs to be updated with the new MAC
address. To have the CutLinc server automatically discover the new MAC address,
delete the following file and then reboot the HMI:
C: > local > Users > Public > Public Documents > CutLinc > Discovery > SND.xml
Alternate IP Addresses
When not using DHCP, the following alternate IP addresses will be assigned by
default after the timeout period shown:
Timeout
180 seconds
10 seconds
~60 seconds
* Must be assigned manually. See instructions below.
The subnet mask is 255.255.255.0.
To manually assign the alternate IP Address for the HMI:
1) On the HMI, navigate to the following:
2) Right-click on the CutLinc adapter (
Properties.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
IP Address
192.168.90.11
192.168.90.12
192.168.90.13*
>
>
Page 45 of 118
FineLine 300HD Plasma System
Component
Power Supply
Automatic Gas Console
HMI
>
) and then choose