Lincoln Electric FineLine 12864 Operator's Manual page 90

300hd plasma system
Table of Contents

Advertisement

FineLine 300HD Plasma System
Error
Telnet
Code
24109
0x100D EX: pac timeout
24110
0x100E EX: remote power off
24111
0x100F
24112
0x1010
24113
0x1011
24114
0x1012
24115
0x1013
24116
0x1014
24611
0x1203
24612
0x1204
25632
0x1600
25634
0x1602
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Automatic Gas Console Specific Errors
Description
EX: Purge in progress
EX: Invalid purge time
EX: Plasma gas pressure too low to
purge
EX: Shield gas pressure too low to
purge
EX: Marking gas pressure too low to
purge
EX: Purge gas hoses before first cut.
NRT: Connection Down
RT: Connection down.
FU: Validate failed.
FU: Invalid image type.
Page 90 of 118
BK8053-000107 Rev A.01
Possible Resolution
1) Verify have OCV.
2) Verify preflow gas pressure
3) Verify ASC powered and
discharging.
4) Verify consumables
Check EStop
Wait for purge to complete.
Verify purge time set within xx
and xx seconds.
1) Verify gas input pressures
within limits.
2) Check for gas leaks or
blockage.
Command manual gas purge.
Check Ethernet cable
Check PS Interconnect cable