11.5

ASSA ABLOY SW300 inverse installation with PULL arm system

Remove the microswitch lever (1), but not the micro switch (2). Remove also the stop arm (3).
Note! Set dip switch INV to ON for Inverse operation, see
Spring pre-tension should not be more than 7 mm (measured between the washer and the adjust-
ment nut).
Closing torque CLTQ can be adjusted to maximum 75%, to avoid motor to be overheated.
Follow step
"INVERSE" text on the operator is visible and do not make step
Open the door in fully
open position. Tighten
the adaptor fixing screw.
1007913-en-20.0
to
on page
48, with the difference that the operator is turned 180° so the
Issue 2021-02-04
1
Microswitch lever
2
Micro switch
3
Stop arm
12.1.1 on page
64.
.
If necessary, adjust by moving the adaptor one step at a time.